Products / Three-phase and multi-channel meters / VM-37

Vantor VM-37

Vantor VM-37

Three Phase DIN Rail Meter + CT / Rogowski Kit - Box of 10

Pricing on request: reseller and end-user price lists.

    Sold in boxes of 10.

    Description:

    This listing is the Vantor VM-37 three-phase DIN-rail smart power meter supplied as a complete measuring set: the meter plus three matched split-core CTs (5 A, 100 A, 400 A or 800 A) or three flexible Rogowski coils (200 A to 2500 A). Everything arrives ready to clip around the busbars or cables, so retrofitting sub-metering to an existing board takes minutes without breaking the conductors. The VM-37 measures all three-phase parameters, four-quadrant energy, run time and harmonics to the 31st order, with RS485 Modbus RTU standard and LoRa, 4G or Wi-Fi communication available as options. For the bare meter with communication options see our standard VM-37 listing.

    Key Features:

    • Complete kit: VM-37 meter + 3 split-core CTs or 3 Rogowski coils

    • CT kits: 5 A (16 mm), 100 A (16 mm), 400 A (22 mm) or 800 A (36 mm) window

    • Rogowski kits: 200 A (50 mm), 600 A (80 mm), 1000 A (150 mm), 2000 A (200 mm) or 2500 A (300 mm) aperture, 2 - 3 m lead

    • Class 0.5S active energy; U/I within 0.2%

    • Four-quadrant energy, multi-tariff, demand, max/min, run time, 2nd - 31st harmonics

    • RS485 Modbus RTU standard; LoRa, 4G or Wi-Fi option (one per meter); dual-source, DI/DO, residual-current and temperature options

    • LCD display, 35 mm DIN-rail mounting

    • Wide-range supply 85 - 305 V AC / 70 - 430 V DC

    Technical Specifications:

    • Model: VM-37 meter supplied as a set with 3 CTs or 3 Rogowski coils (select below)

    • Accuracy: active energy Class 0.5S; U/I +/-0.2%

    • Voltage: 3 x 220/380 V rated (57.7/100 and 380/660 V options)

    • Current: via supplied CTs (5 A secondary) or Rogowski coils; programmable ratio

    • Harmonics: 2nd - 31st

    • Communication: RS485 Modbus RTU; optional LoRa (-L), 4G (-4G) or Wi-Fi (-Wi)

    • I/O: 4 DI, 2 DO standard; options for residual current (LD45/LD100/LD200), 4-wire temperature, 24 V backup

    • Mounting: 35 mm DIN rail

    • Auxiliary supply: 85 - 305 V AC / 70 - 430 V DC, < 3 VA

    Ordering Options (sold in boxes of 10):

    • VM-37-W - VM-37-W - meter + 3 x 5 A CTs

    • VM-37-W100 - VM-37-W100 - meter + 3 x 100 A CTs (16 mm)

    • VM-37-W400 - VM-37-W400 - meter + 3 x 400 A CTs (22 mm)

    • VM-37-W800 - VM-37-W800 - meter + 3 x 800 A CTs (36 mm)

    • VM-37-R200 - VM-37-R200 - meter + 3 x 200 A Rogowski (50 mm)

    • VM-37-R600 - VM-37-R600 - meter + 3 x 600 A Rogowski (80 mm)

    • VM-37-R1000 - VM-37-R1000 - meter + 3 x 1000 A Rogowski (150 mm)

    • VM-37-R2000 - VM-37-R2000 - meter + 3 x 2000 A Rogowski (200 mm)

    • VM-37-R2500 - VM-37-R2500 - meter + 3 x 2500 A Rogowski (300 mm)

    Lead Time:

    8 - 10 Days (imported to order).

    Kit

    VM-37-W - meter + 3 x 5 A CTsVM-37-W100 - meter + 3 x 100 A CTs (16 mm)VM-37-W400 - meter + 3 x 400 A CTs (22 mm)VM-37-W800 - meter + 3 x 800 A CTs (36 mm)VM-37-R200 - meter + 3 x 200 A Rogowski (50 mm)VM-37-R600 - meter + 3 x 600 A Rogowski (80 mm)VM-37-R1000 - meter + 3 x 1000 A Rogowski (150 mm)VM-37-R2000 - meter + 3 x 2000 A Rogowski (200 mm)VM-37-R2500 - meter + 3 x 2500 A Rogowski (300 mm)

    ← Back to three-phase and multi-channel meters